title: "FAQ"
search_description: "Which are the steps to start a project? Follow the steps here."
published: 2026-11-09 17:15:11.218764+00:00
locale: "en"
---

# FAQ

![doctor-examining-test-tubes-in-medical-lab\_2](/media/images/doctor-examining-test-tubes-in-medical-lab_2.width-1500.jpg)

**Margine verticale:** Medio
### Schede

**Titolo:** General
### Contenuto

### How do I start a project with IGATech?

Five steps: \(1\) send an enquiry through the contact form for a free consultation; \(2\) review your quotation on the Customer Portal; \(3\) download the sample guideline for your application; \(4\) attach a purchase order and activate the project on the portal; \(5\) fill in the shipment page with the sample spreadsheet and follow the Shipping and Packaging Guidelines.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What does the Customer Portal show me after activation?

Sample arrival and condition, QC results \(with a contact person if samples are out of specification\), a notification when results are ready, and the data download area.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Which documents must travel with my samples?

The application guideline, the matching spreadsheet and, for human tissue or body fluid, the signed Human samples clearance form. If the project was activated on the portal, attach the spreadsheet there and put the printed shipment barcode in the parcel; if the quotation came by email, send the spreadsheet both in the parcel and by email, together with the tracking number.

Spreadsheets:

- Samples Spreadsheet M07\_04 – DNA or RNA for library preparation
- Libraries Spreadsheet M07\_18 – ready-made libraries or pools \(Run Only\)
- Samples Spreadsheet Metabarcoding M07\_17 – DNA or amplicons for metabarcoding
- Single-cell RNA Samples Spreadsheet M07\_19 – cell or nuclei suspensions
- Biomaterial Samples Spreadsheet M07\_20 – raw material for extraction

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Who do I contact for technical questions?

Write to the application mailbox; requests are answered within two working days.

- Extraction \(biomaterial\): [dna-rna-extraction@igatechnology.com](mailto:dna-rna-extraction@igatechnology.com)
- DNA-seq, exome, target sequencing: [dna-seq@igatechnology.com](mailto:dna-seq@igatechnology.com)
- Transcriptomics: [transcriptomics@igatechnology.com](mailto:transcriptomics@igatechnology.com)
- Single-cell: [single-cell@igatechnology.com](mailto:single-cell@igatechnology.com)
- Epigenomics \(ChIP-seq, ATAC-seq, BS/EM-seq\): [epigenomics@igatechnology.com](mailto:epigenomics@igatechnology.com)
- Long reads and Hi-C: [long-read@igatechnology.com](mailto:long-read@igatechnology.com)
- Genotyping: [genotyping@igatechnology.com](mailto:genotyping@igatechnology.com)
- Metabarcoding, metagenomics, metatranscriptomics: [metagenomics@igatechnology.com](mailto:metagenomics@igatechnology.com)
- Custom libraries Illumina: [Illumina@igatechnology.com](mailto:Illumina@igatechnology.com)
- Custom libraries Element AVITI: [element-bioscience@igatechnology.com](mailto:element-bioscience@igatechnology.com)

### What happens if my samples do not meet the specifications?

You are informed at QC and decide whether to proceed or send replacements. Proceeding with non-compliant samples releases IGATech from liability for poor libraries or low yield, and the full service fee applies. Extra processing \(purification, normalisation, low-input protocols, in-process QC\) can be charged and turnaround may be delayed.

### Can IGATech extract DNA or RNA for me?

Yes: from plants, animal tissues, soil, stool, skin, food, cell and bacterial pellets, water filters, FFPE, blood and dried blood spots. A dedicated workflow can be set up for other substrates. Requirements per matrix are listed in the Sample logistics section.

### Can I send human samples?

Yes, pseudonymised. Samples must not carry personal identification data \(name, fiscal code\); study data that do not identify a person \(age, sex, biometric values, prognosis\) can be added to the spreadsheet. Human tissue or body fluid needs the signed Human samples clearance form. Questions on GDPR, consent or clinical use: see the Terms and Conditions \(M12\_01\) and the Privacy Information, or contact IGATech.

### Where do I find how my samples were processed?

In the PDF report delivered with the data: it describes methods, materials and every delivered file.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

### What happens to leftover samples and data after delivery?

Sample return, data storage and data delivery terms are set in the general Terms and Conditions \(M12\_01\), available on the Documents page.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

### What sequencing depth should I ask for?

There is no universal number: it depends on application, field and journal. Each base must be read several times, coverage is never even, and rare variants in heterogeneous samples or rarely expressed genes need more depth. Recommended depth for each sub-application, with references, is given in the section of each application.

**Titolo:** Sample logistics
### Contenuto

### Which containers do you accept?

Up to 24 samples: 1.5 mL or 2 mL tubes sealed with parafilm \(or safe-lock lids\). More than 24 samples: 96-well plates sealed with adhesive or heat-sealed aluminium foil, or strip caps, each plate labelled with the identifier used in the spreadsheet. Accepted plates include Thermo Fisher MicroAmp Optical \(N8010560\), Eppendorf twin.tec PCR \(0030 128.672\) and Sarstedt half-skirt 200 µL \(72.1979\) or similar; ship plates inside a tip-box insert so they cannot bend. 0.5 mL and 0.2 mL tubes and strips are not accepted. Genotyping is plate-only \(tubes only for replacement batches under 8 samples\).

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How should I label my samples?

One short progressive number or name per sample, written on the cap \(not only on the box\) with a waterproof black or blue marker, matching the spreadsheet exactly. Labels: at most 12 characters, no spaces or special characters, dashes to separate letters and numbers. Keep details \(date, kit, origin\) in the spreadsheet, not on the tube. Ship large batches in sequential order.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Which labelling mistakes cost time or money?

Long or duplicate names, labels that differ from the spreadsheet, random tube order, labels only on the outer box, and labels that smudge or fall off. Re-labelling, identity checks, manual sorting and layout reconstruction can be charged as extra processing.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Which spreadsheet fields are mandatory?

Sample type, species \(Latin binomial\), volume \(µL\), concentration \(ng/µL\), storage buffer or extraction kit, the quotation number and the contact persons; for plates, plate ID and well position. For the standard analyses of RNA-seq, ChIP-seq and metagenomics, also give the comparisons \(e.g. Group1\_vs\_Group2\). Extra metadata columns are welcome: they drive statistics and plot colouring.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Should I send a back-up aliquot?

Yes, where possible. A second aliquot lets the lab repeat an extraction or a library with adjusted input instead of waiting for new material.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Which buffer should my DNA or RNA be in?

DNA: nuclease-free water or 10 mM Tris-HCl pH 8.5. Avoid EDTA where possible, because it chelates the Mg2+ that library enzymes need; DNA containing EDTA up to 0.5 mM \(e.g. low-EDTA TE\) is accepted. For bisulfite or enzymatic methyl-seq, nuclease-free water is preferred. RNA: nuclease-free water or low-EDTA TE buffer. If a non-standard buffer is unavoidable, agree it before shipping.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Why do you ask for fluorometric quantification?

Absorbance \(NanoDrop\) also measures RNA, free nucleotides and residual CTAB or phenol, so it can largely overestimate DNA. All concentration limits in the guidelines refer to Qubit or other dsDNA-specific dyes. If you can only measure by absorbance, send twice the required amount \(genotyping: at least 50 ng/µL and 1 µg\). A260/280 and A260/230 should both be above 1.8.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Why must concentrations be even across a batch?

Pooled workflows \(genotyping, amplicons, multiplexed libraries\) share reads in proportion to input. IGATech asks for every sample within ±20% of the batch mean and checks this on a random subset. Outside the range, quantification and normalisation are charged or, if you waive normalisation, per-sample coverage is not guaranteed.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I check integrity before shipping?

Genomic DNA: a 0.8% agarose gel showing a high-molecular-weight band with little smear \(genotyping needs fragments above 20 kb\). RNA: RIN above 8 on a Bioanalyzer, or a gel with the 28S band \(4.5 kb\) about twice as intense as 18S \(1.9 kb\). Include the trace or gel image with the submission.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How can I remove contaminants or inhibitors?

Ethanol precipitation, silica columns or magnetic beads remove salts, proteins and most inhibitors; column clean-up is recommended after any phenol or CTAB extraction. Treat DNA with RNase and total RNA with DNase I. Diluting a sample also dilutes inhibitors but lowers sensitivity, which matters in metabarcoding. Extra purification can be ordered from IGATech.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How much starting material should I send for extraction, and how?

Flash-freeze fresh tissue at collection, avoid freeze–thaw and send duplicates.

- Plant tissue, DNA: 10–30 mg lyophilised or 40–120 mg fresh; 1.5 mL tubes \(under 8 samples\) or QIAGEN Collection Microtubes 19560 with caps 19566; lyophilised at room temperature, fresh on dry ice
- Plant tissue, HMW DNA: at least 10–15 g young leaves or buds in 15/50 mL Falcon tubes; dry ice
- Plant tissue, RNA: 2 mL tube or Falcon; dry ice, or in GenTegraRNA, GENEWIZ RNA or Zymo DNA/RNA Shield \(RNAlater: ask first\)
- Animal tissue, DNA: up to 25 mg \(spleen up to 10 mg\) per 1.5/2 mL tube; dry ice
- Animal tissue, RNA: up to 30 mg per tube; dry ice, stabiliser recommended
- Soil: at least 250 mg in sealed 1.5–50 mL tubes; DNA at room temperature, cold packs or dry ice; RNA on dry ice or in RNAlater/RNAProtect
- Skin: DNA at least 25 mg; RNA up to 100 mg
- Food \(DNA only\): at least 25 mg
- Cultured cells: DNA and RNA as cell pellets on dry ice \(RNA from 10^4 to 10^7 cells\)
- Bacterial pellet \(BSL-1 only\): at least 250 mg pelleted biomass; tubes up to 48 samples, deep 96-well plate above; dry ice; RNase inhibitor for RNA; state Gram type or spores; no liquid cultures or slants
- Water filters: sealed, lock plugs closed, each in its own bag; DNA with cold packs or dry ice; RNA in RNAlater/RNAProtect on dry ice
- FFPE: 3–4 sections of 5–10 µm, 20–200 mm2 each, max 2 mm3 total; dry, room temperature, never in ethanol or xylene
- Whole blood, DNA: original EDTA tube or aliquot of at least 500 µL \(1–2 mL preferred\); frozen, dry ice
- Whole blood, RNA: in PAXgene, Tempus, DNA/RNA Shield or equivalent; dry ice
- Dried blood spots \(DNA only\): at least 4 full spots on Whatman 903 or equivalent, sealed with desiccant
- Stool: see “How do I collect and ship stool samples?”

Contact the lab before shipping more than 24 soil or filter samples.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I collect and ship stool samples?

Up to 48 samples: 0.5–1 g of faeces in a Zymo R1103 tube pre-filled with 1 mL DNA/RNA Shield and 0.5 mm beads, leaving at least 30% of the tube empty. Above 48 samples: deep 96-well plates with 600 µL of suspension per well, sealed with heat-resistant, pierceable seals. Faeces frozen without preservative or stored in ethanol must be transferred into DNA/RNA Shield \(ethanol samples pelleted and washed in PBS first\). Ship in a sealed bag inside a padded box at room temperature.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I pack the parcel?

Use a box of the right size with bubble wrap, no empty space and nothing rolling. Bag and wrap plates. Cool with frozen ice packs or dry ice, never wet ice. Cryotubes go into a cryobox so they do not touch dry ice directly. Cells: overnight courier, delivery by 12:00.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Can I ship RNA without dry ice?

Yes, if dried in GenTegraRNA or GENEWIZ RNA Stabilization Tubes; otherwise use plenty of dry ice so it does not run out in transit.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Which transport rules apply to my parcel?

Dry ice is always regulated: the outer box must carry the Class 9 label, 'UN 1845 Dry ice' \(or 'Carbon dioxide, solid'\) and the net dry-ice weight in kg, and must let CO2 escape. Raw human or animal specimens may travel as 'exempt specimens' or as UN 3373 Biological Substance Category B, which needs triple packaging \(leak-proof primary receptacle, leak-proof secondary packaging with absorbent, rigid outer packaging\). Your courier and institutional safety officer decide the classification.

References: [UCL Safety Services](https://www.ucl.ac.uk/safety-services/a-z/dangerous-goods/transporting-infectious); [MSF UniCat](https://unicat.msf.org/intros/24332)

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I announce the shipment?

On the Customer Portal, add a shipment with courier and tentative date, attach the spreadsheet, and put the printed shipment barcode in the box. For quotations received by email, email the spreadsheet and the tracking number.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Where do I ship?

IGA Technology Services srl, c/o Parco Scientifico e Tecnologico "Luigi Danieli", via Jacopo Linussio 51, 33100 Udine \(Z.I.U.\), Italy.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

**Titolo:** WGS & Exome
### Contenuto

### What coverage do I need for WGS and exome?

There is no single official number: it depends on the variant type, the sample and the journal, and coverage is never perfectly even. Reference values by sub-application:

- Human germline WGS: at least 30x mean coverage \(30–50x depending on application and statistical model\)
- Somatic tumour–normal WGS: benchmarking showed benefits up to about 100x, provided tumour and normal coverage stay balanced; the pan-cancer PCAWG genomes averaged 39x for normals and about 38x or 60x for tumours. Low purity or subclonal targets need more
- Low-pass WGS with imputation \(GWAS, polygenic scores\): an effective coverage of 0.4–0.5x or more already gives more accurate imputed genotypes than a GWAS array; 0.5–1x performs like low-density arrays
- Germline exome: mean of 100x or more \(70x for trio members\) with 90–95% of targets at 10x or more; 20x at a base gives about 99% sensitivity for heterozygous SNVs
- Somatic exome: more than 250x in the tumour limits false positives in subclonal calls
- Population resequencing of individuals: almost all homozygous SNVs at about 15x, heterozygous SNVs need about 33x; for population-level inference, many samples at low depth \(e.g. 400 samples at 4x\) analysed with genotype likelihoods
- Pooled sequencing \(Pool-seq\): no fixed target; pool size matters as much as depth
- Polyploid crops: about 12 reads per site to see all alleles of a tetraploid, several hundred to call allele dosage
- Bacterial hybrid assembly: long reads at least 100x \(200x ideal\) plus short reads about 100x

Coverage = read length x number of reads / genome size.

References: [Rehm 2013 \(ACMG\)](https://www.nature.com/articles/gim201392); [Illumina, Sequencing coverage](https://www.illumina.com/science/education/sequencing-coverage.html); [Alioto 2015](https://doi.org/10.1038/ncomms10001); [PCAWG 2020](https://doi.org/10.1038/s41586-020-1969-6); [Li 2021](https://genome.cshlp.org/content/31/4/529.full); [Martin 2021](https://pubmed.ncbi.nlm.nih.gov/33770507/); [Patwardhan 2015](https://link.springer.com/article/10.1186/s13073-015-0197-4); [Shi 2018](https://www.biorxiv.org/content/10.1101/253195); [Sims 2014](https://doi.org/10.1038/nrg3642); [Carvalho 2023](https://eprints.whiterose.ac.uk/201836/); [Wang 2022](https://pubmed.ncbi.nlm.nih.gov/34826191/); [Wick 2023](https://pubmed.ncbi.nlm.nih.gov/36862631/)

### Full-coverage WGS, low-pass WGS or exome?

Full-coverage WGS calls coding and non-coding variants, CNVs and structural variants with the most uniform coverage. Low-pass WGS \(low coverage followed by imputation\) is the cost-effective choice for population studies and GWAS on large cohorts. Exome captures exons and splice junctions \(expandable with custom targets\) and is cheaper per sample, but coverage is less uniform and SV/CNV calling is limited. For the depth of each option, see “What coverage do I need for WGS and exome?”

References: [Samorodnitsky 2015](https://pmc.ncbi.nlm.nih.gov/articles/PMC4832303/)

### Standard, low-input or PCR-free library?

PCR-free libraries avoid amplification duplicates and need more DNA \(5–100 ng/µL, 25 µL\). Standard libraries work from 1–50 ng/µL; below 1 ng/µL a low-input protocol is used, at extra cost.

### How should I sequence a bacterial genome or a plasmid?

For a closed chromosome and complete plasmids, long reads assemble the replicons and short reads polish residual errors; this hybrid, long-read-first route is the current reference approach. Long-read-only assemblers often miss or misassemble small plasmids, so tell us if small plasmids matter. Short reads alone suit large SNP-typing or screening batches. For depth, see “What coverage do I need for WGS and exome?”

References: [Wick 2023](https://pubmed.ncbi.nlm.nih.gov/36862631/); [Bouras 2023](https://pmc.ncbi.nlm.nih.gov/articles/PMC10760025/)

### Can I get mitochondrial or chloroplast genomes from WGS?

Yes: organelle reads are extracted from the nuclear data. Copy number depends on cell type; as an order of magnitude, human WGS at 30–40x from peripheral blood gives about 3,000–4,000x mitochondrial coverage. In exomes, at least 20x per mtDNA base detects most mtDNA SNVs.

### What DNA do you need for WGS and exome?

- Standard DNA-seq: 1–50 ng/µL \(fluorimetry\), at least 25 µL
- Low-input DNA-seq: below 1 ng/µL, at least 25 µL \(more if possible\)
- PCR-free DNA-seq: 5–100 ng/µL, at least 25 µL
- Exome: 10–40 ng/µL in 10 mM Tris-HCl pH 8.5, at least 35 µL

In all cases: water or 10 mM Tris-HCl pH 8.5, EDTA up to 0.5 mM, A260/280 and A260/230 above 1.8, RNase-treated, high molecular weight, all samples within ±20% of the batch mean. FFPE DNA is accepted at extra cost.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Why do you ask for fluorometric quantification?

Absorbance \(NanoDrop\) also measures RNA, free nucleotides and residual CTAB or phenol, so it can largely overestimate DNA. All concentration limits in the guidelines refer to Qubit or other dsDNA-specific dyes. If you can only measure by absorbance, send twice the required amount \(genotyping: at least 50 ng/µL and 1 µg\). A260/280 and A260/230 should both be above 1.8.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Why must concentrations be even across a batch?

Pooled workflows \(genotyping, amplicons, multiplexed libraries\) share reads in proportion to input. IGATech asks for every sample within ±20% of the batch mean and checks this on a random subset. Outside the range, quantification and normalisation are charged or, if you waive normalisation, per-sample coverage is not guaranteed.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What do I send for bacterial genome sequencing?

Purified DNA as in “What DNA do you need for WGS and exome?” \(long-read specifications in the Long reads & Assembly tab\), or at least 250 mg of pelleted biomass on dry ice for extraction \(BSL-1 organisms only, no liquid cultures or slants\). State Gram type or spores in the spreadsheet.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What bioinformatics is available for WGS and exome?

- Standard: read QC, alignment, germline SNP, indel and SV calling, coverage statistics
- Advanced: somatic SNVs and SVs, clonal fingerprinting and parentage, chromosomal abnormalities, event-specific insertion analysis
- Human exome: functional annotation, trio and tumour–normal analysis, compound heterozygotes, mitochondrial variants, tumour mutational burden, CNV/SV on request
- Nanopore: phased SNPs and SVs, phased methylation
- Bacteria: annotated genomes and plasmids, resistance genes, mutation analysis, pathogen identification, comparative genomics; or demultiplexed FASTQ with QC

### What usually goes wrong in DNA sequencing projects?

- Degraded or over-sheared DNA gives short inserts and low library complexity
- Residual phenol, CTAB or salts inhibit library enzymes, and NanoDrop values hide the problem
- Uneven concentrations across a batch give uneven per-sample depth
- Long-read-only bacterial assemblies can miss small plasmids

References: [Bouras 2023](https://pmc.ncbi.nlm.nih.gov/articles/PMC10760025/)

**Titolo:** Long reads & Assembly
### Contenuto

### When do I need long reads rather than short reads?

When the question involves repeats, structural variants, haplotype phasing, complete genomes or plasmids, full-length transcript isoforms, or base modifications read directly on native DNA \(4mC, 5mC, 5hmC, 6mA\). Adaptive sampling can enrich target regions without PCR.

### What read length will I get?

Read length is set by your DNA, not by the instrument. Standard libraries typically give an N50 of tens of kilobases; ultra-long libraries \(reads above 50 kb\) need DNA extracted with dedicated HMW methods. A gentle bead-based extraction with size selection has been reported to give read N50 values of 30–50 kb, with reads above 200 kb.

References: [Jones 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8282028/)

### How is a chromosome-scale, phased assembly built?

Long reads build the contigs, Hi-C contact data order and orient them into chromosomes \(with genetic maps for anchoring when available\), and long reads plus Hi-C separate the two haplotypes. Gene prediction, annotation, pangenome analysis and a private genome browser are available on top. For depth, see “How much long-read coverage is needed for a de novo genome?”

### What must I tell you about my genome?

The estimated genome size is mandatory in the spreadsheet: it sets the amount of sequencing. For amplicons, the expected amplicon length is mandatory.

### How much long-read coverage is needed for a de novo genome?

Figures for a diploid eukaryote; scale with ploidy and heterozygosity:

- PacBio HiFi: more than 12.5x per haplotype, ideally up to 20x \(more than 25x in total\)
- Oxford Nanopore: more than 20x per haplotype, with read N50 around 50 kb
- Telomere-to-telomere: more than 60x HiFi plus more than 40x ultra-long Nanopore
- Plant genomes on Nanopore: at least 30x for haploid or diploid genomes, plus about 15x for each additional ploidy level
- Hi-C for scaffolding: more than 50x \(see the Hi-C depth question in this tab\)

Reference quality targets \(Vertebrate Genomes Project\): contig NG50 of at least 1 Mb, scaffold NG50 of at least 10 Mb, consensus accuracy QV40 and at least 90% of the sequence assigned to chromosomes. Bacterial genomes: see the WGS & Exome tab.

References: [Earth BioGenome Project assembly recommendations](https://www.earthbiogenome.org/report-on-assembly-recommendations); [Oxford Nanopore, plant assembly workflow](https://nanoporetech.com/api/assets/f/196663/x/d6cca53e21/plant-assembly-workflow.pdf); [Rhie 2021](https://www.nature.com/articles/s41586-021-03451-0)

### How deep should I sequence Hi-C for assembly, compartments, TADs or loops?

Depth depends on the question; counts are read pairs unless stated, and only a fraction become valid contacts.

- Genome scaffolding \(chromosome-scale assembly\): more than 50x coverage of the haploid genome \(more than 100x if Hi-C reads are also used for polishing\); the Vertebrate Genomes Project sequenced Hi-C at about 60x. Vendor guidance converts to about 200 M paired-end reads per Gb of genome, with more for fragmented contigs
- A/B compartments: the least demanding goal, readable from sparse data; vendor guidance is more than 50 M reads, analysed at 1–10 Mb bins
- TADs: about 100 M valid \(mapped junction\) reads support 40 kb resolution in human, the bin size used when TADs were first defined; vendor guidance is more than 200 M reads, and finer bins need more
- Chromatin loops \(5–10 kb\): at least 600 M read pairs per sample and at least two samples; the human kilobase-resolution reference map used 4.9 billion contacts. There is no formal minimum: sparser maps simply call fewer loops
- Resolution is defined as the smallest bin size at which 80% of bins have at least 1,000 contacts

References: [Earth BioGenome Project assembly recommendations](https://www.earthbiogenome.org/report-on-assembly-recommendations); [Rhie 2021](https://www.nature.com/articles/s41586-021-03451-0); [Arima, Hi-C for genome assembly](https://arimagenomics.com/wp-content/files/eBook-Hi-C-for-Genome-Assembly.pdf); [Arima, Hi-C for 3D genome](https://arimagenomics.com/wp-content/files/Product-Flyer-The-Arima-HiC-Kit-for-Reproducible-3D-Genome-Conformation-Analyses.pdf); [Lajoie 2015](https://pmc.ncbi.nlm.nih.gov/articles/PMC4347522/); [Dixon 2012](https://pmc.ncbi.nlm.nih.gov/articles/PMC3356448/); [Arima, Bioinformatics user guide](https://arimagenomics.com/wp-content/files/Bioinformatics-User-Guide-Arima-HiC-and-Arima-High-Coverage-HiC.pdf); [Rao 2014](https://doi.org/10.1016/j.cell.2014.11.021)

### What DNA do you need for long-read sequencing?

- Standard long-read library: above 20 ng/µL \(fluorimetry\), at least 100 µL
- Ultra-long library: above 100 ng/µL, at least 300 µL, extracted with HMW methods \(e.g. QIAGEN Genomic-tip, NEB Monarch HMW\)
- Samples to be barcoded and pooled: above 40 ng/µL \(above 100 ng/µL with 4 barcodes or fewer\), at least 20 µL
- Amplicons: above 20 fmol/µL \(about 13 ng/µL per 1 kb\), at least 25 µL

Buffer: water or 10 mM Tris-HCl pH 8.5.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Can you extract HMW DNA for me?

Yes, from plants: send at least 10–15 g of flash-frozen, intact young leaves or buds in 15/50 mL Falcon tubes on dry ice, in duplicate. With less tissue, ask first.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What material do you need for Hi-C?

Plants: at least 10 g of flash-frozen young leaves or buds in 15/50 mL Falcon tubes on dry ice. Mammalian cells: frozen cell suspension in duplicate, 5 x 10^6 cells in 1 mL per cryotube recommended \(minimum 100,000 cells in 0.5 mL\); ask first below 1 million cells or above 24 samples. Ship on dry ice overnight for delivery by 12:00, cryotubes in a cryobox. Live cells can be hand-delivered for same-day processing if planned.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I keep DNA long?

Read length is limited by the length and purity of the input DNA. Avoid spin columns and high-speed centrifugation, which fragment DNA; prefer gentle bead-based clean-up with size selection, and check fragment size before shipping.

References: [Jones 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8282028/)

### What do you deliver for long-read and assembly projects?

Telomere-to-telomere or chromosome-scale assemblies, phased diploid assemblies, annotation, pangenome analysis, genome browser hosting; for resequencing, SNV, SV, STR and CNV calling, haplotype phasing and haplotype-specific methylation.

### What usually goes wrong with long reads?

- Polysaccharides and polyphenols co-purify with plant DNA and inhibit downstream steps; young tissue and nuclei isolation or sorbitol washes help
- Over-fragmented DNA caps read length whatever the chemistry
- An underestimated genome size leads to too little coverage
- Absorbance-only quantification overestimates input

References: [Jones 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8282028/)

**Titolo:** Targeted sequencing
### Contenuto

### Hybrid capture or amplicon panel?

- Hybridisation capture: hundreds of genes to a whole exome, higher DNA input, more off-target reads but better coverage uniformity; suited to exomes, large panels, rare variants and CNVs
- Amplicon \(PCR\) panels: tens to a few thousand amplicons, low input, works on FFPE and degraded DNA, higher on-target rate but lower uniformity; suited to small panels, known hotspots and genome-editing checks

References: [Singh 2022](https://pmc.ncbi.nlm.nih.gov/articles/PMC9318977/); [Samorodnitsky 2015](https://pmc.ncbi.nlm.nih.gov/articles/PMC4832303/)

### How deep should I sequence a targeted panel?

Depth is set by the lowest variant allele fraction \(VAF\) you must detect and by how many independent DNA molecules you start from:

- Germline exome or panel: mean of 100x or more, with at least 20x per base \(see the WGS & Exome tab\)
- Somatic panels without molecular barcodes: more than 250 reads per target \(AMP/CAP validation guideline\); detecting 3% VAF with at least 30 mutant reads needs about 1,650x
- Panels with UMIs for low VAF: raw depth is roughly the number of mutant molecules required divided by the VAF, times the read-family size; for example, 5 mutant molecules at 1% VAF need about 5,000x raw depth and at 0.5% about 10,000x. Simplex UMIs reach about 0.1% VAF at about 15,000x raw depth
- Duplex-seq: the lowest error floor \(theoretically below one error per 10^9 bases\) but fewer retained molecules; IGATech's assay targets variants around 0.1%

Input caps sensitivity: deeper sequencing cannot find variants in molecules that were never in the tube.

References: [Rehm 2013 \(ACMG\)](https://www.nature.com/articles/gim201392); [Jennings 2017 \(AMP/CAP\)](https://stacks.cdc.gov/view/cdc/83997); [Petrackova 2019](https://www.frontiersin.org/journals/oncology/articles/10.3389/fonc.2019.00851/full); [Takara Bio, Tag-seq sequencing depth](https://takarabio.com/learning-centers/next-generation-sequencing/technology-and-application-overviews/sequencing-depth-for-thruplex-tag-seq); [Revvity, simplex and duplex UMIs](https://www.revvity.com/blog/assessing-error-suppression-strategies-technical-review-simplex-and-duplex-umis); [Schmitt 2012](https://pubmed.ncbi.nlm.nih.gov/22853953/)

### What is Duplex-seq and when do I need it?

Duplex sequencing tags both strands of each original DNA molecule and keeps only mutations seen on both, which removes most PCR and sequencing errors \(theoretical background below one error per 10^9 bases\). Use it for ultra-rare somatic variants, mutagenesis or mixed populations; IGATech's targeted Duplex-Seq assay detects variants at around 0.1%. It needs at least 1 µg of DNA and deep sequencing.

References: [Schmitt 2012](https://pubmed.ncbi.nlm.nih.gov/22853953/)

### Can you design a panel for my species?

Yes: pre-designed panels or custom capture designs, for human and other species, including extra targets beyond exons.

### What DNA do you need for targeted sequencing?

- Exome-seq and capture panels: 10–40 ng/µL \(fluorimetry\), at least 35 µL
- Integrome and Duplex-seq: 20–30 ng/µL, at least 1 µg total, at least 35 µL

Diluent 10 mM Tris-HCl pH 8.5 \(EDTA up to 0.5 mM\), A260/280 and A260/230 above 1.8, RNase-treated, high molecular weight, all samples within ±20%. With NanoDrop values only, send twice the amount. FFPE or highly degraded DNA is accepted at extra cost.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Why do you ask for fluorometric quantification?

Absorbance \(NanoDrop\) also measures RNA, free nucleotides and residual CTAB or phenol, so it can largely overestimate DNA. All concentration limits in the guidelines refer to Qubit or other dsDNA-specific dyes. If you can only measure by absorbance, send twice the required amount \(genotyping: at least 50 ng/µL and 1 µg\). A260/280 and A260/230 should both be above 1.8.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What analyses come with a targeted project?

Variant calling and functional annotation, trio and tumour–normal analysis, compound heterozygote filtering, mitochondrial variants, tumour mutational burden, and CNV/SV calling on request.

### Why is coverage uneven across my targets?

Multiplex PCR primers differ in melting temperature and GC content, so some amplicons amplify better than others; capture probes also hybridise with different efficiency. GC-rich regions \(5′ UTRs, promoters, first exons\), repeats, tandem repeats, pseudogenes and low-quality or low-quantity DNA add further bias. Amplicon methods show higher on-target rates, capture methods better uniformity.

References: [Samorodnitsky 2015](https://pmc.ncbi.nlm.nih.gov/articles/PMC4832303/)

### What else goes wrong in targeted sequencing?

- Amplicon methods can miss variants and report discordant ones because of limited coverage, low variant frequency or proximity to read ends; use a variant caller suited to the enrichment method
- Uneven input across samples gives uneven per-sample depth unless normalisation is ordered
- Below about 1% allele fraction, standard PCR and sequencing errors mask true variants: use molecular barcodes or duplex sequencing

References: [Samorodnitsky 2015](https://pmc.ncbi.nlm.nih.gov/articles/PMC4832303/); [Schmitt 2012](https://pubmed.ncbi.nlm.nih.gov/22853953/)

**Titolo:** Genotyping & Editing
### Contenuto

### ddRAD, SPET or multiplex amplicons?

- ddRAD: thousands to hundreds of thousands of random loci, no prior knowledge needed \(de novo or reference pipeline\); for diversity, population structure and linkage maps in any species
- SPET targeted genotyping \(Allegro, Tecan\): about 1,000 to 100,000 chosen loci, panels reusable across populations and batches; for breeding, GWAS and germplasm collections
- Multiplex amplicons: tens to about 100 known loci across thousands of samples; for fingerprinting

### How many markers will ddRAD give me?

Standard complexity \(about 4 M reads per sample\) targets about 10,000–30,000 polymorphic loci for genomes under 3 Gb; high complexity \(about 12 M reads per sample\) is advised for larger genomes or more loci. Each locus is about 200 bp and typically carries 3–10 SNPs. Reads are 150 bp paired-end on NovaSeq X Plus.

### How deep should genotyping-by-sequencing be?

- ddRAD at IGATech: about 4 M reads per sample \(standard complexity, 10,000–30,000 polymorphic loci for genomes under 3 Gb\) or about 12 M reads per sample \(high complexity, larger genomes or more loci\)
- Genotype accuracy: more than 30 reads per locus per individual bring error rates to 0.01 or lower with a reference genome; de novo-assembled loci kept error rates above 0.04 even at high coverage, so a reference improves calls
- Polyploids: about 12 reads per locus to see all alleles of a tetraploid; several hundred to call allele dosage reliably

Uneven DNA input across samples is the main cause of samples falling below these thresholds.

References: [Fountain 2016](https://core.ac.uk/download/519313627.pdf); [Wang 2022](https://pubmed.ncbi.nlm.nih.gov/34826191/)

### Why choose SPET instead of a SNP array?

Arrays only read catalogued SNPs and carry ascertainment bias. SPET sequences the region next to each probe, so it genotypes the target SNP and discovers new, closely linked variants; off-target reads further reduce bias in diversity estimates. Pre-designed panels exist for crops and forest trees \(e.g. maize 50k, grape 60k, tomato 5k/10k, barley 90k\).

References: [Scaglione 2019](https://pmc.ncbi.nlm.nih.gov/articles/PMC6821380/)

### What information should I put in the ddRAD spreadsheet?

Population labels if you want pairwise diversity and inbreeding statistics \(otherwise all samples form one metapopulation\); cross type, parents and progeny for mapping populations; and the reference genome link if you want the reference pipeline instead of de novo.

### How do you check genome-edited plants?

The 360 Genome Editing QC service uses whole-genome sequencing to verify the edit, its stability, off-target mutations and chromosomal alterations before propagation and field investment.

### What DNA do you need for genotyping?

10 mM Tris-HCl pH 8.5, avoiding EDTA \(accepted up to 0.5 mM, as EDTA interferes with the first enzymatic reaction\), 20–50 ng/µL by fluorimetry, at least 30 µL, fragments above 20 kb, every sample within ±20%. With NanoDrop values only, send at least 50 ng/µL and 1 µg. Use column or bead extractions: CTAB or phenol leftovers inhibit enzymes and inflate NanoDrop readings.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I ship genotyping samples?

In full 96-well plates, sealed and labelled with the plate ID; tubes only for replacement batches under 8 samples. Put samples of different origin, tissue, extraction or age on separate plates and declare it in the spreadsheet. IGATech can also extract DNA from leaves or animal tissue.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What do I receive from a genotyping project?

Genotype tables for targeted SNPs and newly discovered alleles, with batch aggregation; optionally diversity and population structure, linkage and QTL mapping, GWAS, and varietal identification or molecular barcoding.

### What usually goes wrong in genotyping projects?

- Uneven DNA concentrations give uneven reads per sample and more missing genotypes
- Allele dropout \(mutations in restriction sites\), PCR duplicates and variance in depth among loci are the main sources of error in RADseq
- Allele dropout slightly underestimates diversity in highly polymorphic species; the bias is minor where polymorphism is below about 2%
- Mixing tissue types or extraction methods on one plate creates batch effects in yield

References: [Andrews 2016](https://www.nature.com/articles/nrg.2015.28); [Cariou 2016](https://pmc.ncbi.nlm.nih.gov/articles/PMC5100275/)

**Titolo:** Transcriptomics
### Contenuto

### How many biological replicates do I need?

More than most people plan. In a 48-replicate yeast study, three replicates per condition found only 20–40% of the differentially expressed genes detected with 42 replicates; finding over 85% of them at any fold change took more than 20. Plan at least six replicates per condition, and 12 or more if small fold changes matter. Extra replicates buy more power than extra depth.

References: [Schurch 2016](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4878611/)

### poly\(A\) selection or rRNA depletion?

rRNA is over 90% of total RNA, so it must be removed. poly\(A\) selection \(stranded mRNA-seq\) is efficient for intact eukaryotic RNA. rRNA depletion \(total RNA-seq\) keeps non-polyadenylated RNAs \(lncRNAs, circRNAs, histone mRNAs\), works better on degraded or FFPE RNA, and is the only option for bacteria. About half of lncRNAs lack a poly\(A\) tail, so poly\(A\) selection biases lncRNA studies.

References: [Conesa 2016](https://pmc.ncbi.nlm.nih.gov/articles/PMC4728800/)

### Will poly\(A\) selection give me a 3′ bias?

Not necessarily: cDNA synthesis uses a mix of random and oligo\(dT\) primers, so gene-body coverage stays balanced on intact RNA. Strong 3′ bias is a sign of degraded input.

### How deep should I sequence each type of RNA-seq?

- mRNA-seq, gene-level differential expression: 30 M aligned reads per replicate \(ENCODE standard, at least two replicates\); beyond about 10 M reads extra depth gives diminishing returns, so spend the budget on replicates \(see the replicates question in this tab\)
- Total RNA-seq \(rRNA depletion\): about 50–220% more reads than poly\(A\) selection for the same exonic coverage, because about half of the reads are intronic
- Alternative splicing: about 100–150 M filtered reads to detect splicing events and 400 M or more for differential splicing; reads of 100 nt or longer improve splice-site resolution, and no saturation point has been found
- Full isoform discovery in human: more than 200 M paired-end reads
- lncRNA and other low-abundance transcripts: more than 80 M reads, or targeted capture; noncoding transcript assembly keeps improving up to about 600 M reads in simulations
- De novo transcriptome \(non-model species\): about 20 M reads for a tissue, 30 M for whole animals
- Small RNA / miRNA: at least 2 M aligned reads per replicate \(ENCODE\); vendor guidance 1–5 M single-end 50 bp reads; for discovery of rare or novel miRNAs about 10 M reads, and the right depth should be checked per tissue
- Ribo-seq: at least 20 M reads per sample for both the Ribo-seq and the matched RNA-seq library, single-end 50 bp, at least three replicates; part of the reads is still rRNA after depletion, so more depth always helps
- Ultra-low input and few-cell full-length libraries: about 1 M reads per sample saturates gene detection
- Nanopore or PacBio full-length cDNA: at least 600,000 full-length non-chimeric reads per replicate is rated good \(400,000–600,000 acceptable\), at least two replicates; read length drives isoform identification, depth drives quantification

References: [ENCODE bulk RNA-seq standards](https://www.encodeproject.org/data-standards/rna-seq/long-rnas/); [Liu 2014](https://academic.oup.com/bioinformatics/article/30/3/301/228651); [Zhao 2018](https://www.nature.com/articles/s41598-018-23226-4); [Liu 2013](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0066883); [Ladwig 2026](https://rnajournal.cshlp.org/content/32/7/993.full); [Sims 2014](https://doi.org/10.1038/nrg3642); [Babarinde 2022](https://link.springer.com/doi/10.1186/s12864-022-08717-z); [Francis 2013](https://pmc.ncbi.nlm.nih.gov/articles/PMC3655071/); [ENCODE microRNA-seq standards](https://www.encodeproject.org/microrna/microrna-seq/); [Illumina, RNA-seq read length and coverage](https://knowledge.illumina.com/library-preparation/rna-library-prep/library-preparation-rna-library-prep-reference_material-list/000001243); [Metpally 2013](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3585423/); [Chothani 2019](https://edoc.mdc-berlin.de/id/eprint/18539/1/18539oa.pdf); [McGlincy 2017](https://escholarship.org/content/qt3929m0fj/qt3929m0fj.pdf); [Svensson 2017](https://pubmed.ncbi.nlm.nih.gov/28263961/); [ENCODE long-read RNA-seq standards](https://www.encodeproject.org/rna-seq/long-read-rna-seq/); [Pardo-Palacios 2024](https://www.usgs.gov/publications/systematic-assessment-long-read-rna-seq-methods-transcript-identification-and)

### Short reads or Nanopore for transcriptomics?

Short reads are the choice for quantification and differential expression. Nanopore full-length cDNA resolves isoform structures and supports de novo annotation; direct RNA reads native molecules and detects modifications such as m6A and pseudouridine.

### What does ribosome profiling add to RNA-seq?

It sequences ribosome-protected fragments from actively translating ribosomes at nucleotide resolution. Combined with mRNA-seq on the same samples, it identifies translationally regulated genes and new translation events.

### What RNA quality do you need?

Nuclease-free water, A260/280 above 1.8, RIN above 8 \(or a gel with 28S twice the intensity of 18S\), free of proteins, phenol, ethanol and salts. Quantify by Qubit and send the Bioanalyzer trace or a gel image. Commercial kits \(e.g. Spectrum Plant Total RNA, TRI Reagent, RNeasy, mirVana\) are recommended, with column clean-up after organic extractions. Degraded RNA gives low yield, over-represented 3′ ends or protocol failure.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How much RNA do I need for each library type?

- Stranded mRNA-seq: 60 ng \(200 ng for de novo\), at least 0.6 ng/µL, 20 µL
- Total RNA-seq, human/mouse/rat: 60 ng, 3 ng/µL, 20 µL
- Total RNA-seq, human/mouse/rat FFPE: 200 ng, 10 ng/µL, 20 µL
- Total RNA-seq, plant, bacterial, metatranscriptome: 200 ng \(2 µg for plant de novo\), 20 ng/µL, 10 µL
- Ultra-low input: 200 pg or 500 cells, 10 pg/µL, 20 µL
- Small RNA-seq: 200 ng total RNA or 20 ng isolated small RNA, 2 ng/µL, 10 µL \(exosomes, serum, plasma: 15 µL of RNA eluate\)
- Nanopore full-length cDNA: 500 ng, 25 ng/µL, 20 µL
- Nanopore direct RNA: 2 µg, 250 ng/µL, 20 µL
- Virus detection by amplicon-seq: 50 µL \(QC after library\)
- Ribosome profiling: frozen cell pellets or frozen tissue, amount agreed case by case

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Do I need a DNase treatment?

Yes for total RNA-seq and metatranscriptomics, where it is mandatory: genomic DNA inflates RNA quantification and adds intronic and intergenic noise. It is not required for mRNA-seq or small RNA-seq.

### Can I go below 100 pg of RNA?

Experimentally yes, but duplicates exceed 50% in IGATech tests. For abundant unwanted transcripts \(rRNA, globin, chloroplast, constitutive mRNAs\) custom depletion with AnyDeplete can be designed.

### What does the RNA-seq analysis include?

- Standard: QC and alignment reports, gene tables \(raw counts, FPKM, TPM\), bedGraph tracks, differential expression \(pairwise and GLM, batch correction\) with PCA, heatmaps, MA and volcano plots and clustering
- Advanced: GO and gene-set enrichment \(DAVID; GSEA for human and mouse\), differential exon and transcript usage, splicing events, SNP and indel calling, protein-interaction networks, ncRNA analysis, de novo assembly, allele-specific expression
- Small RNA: size profiles, ncRNA classes, miRBase and piRNA matching, novel miRNA and target prediction, differential expression, virus discovery

### How are counts normalised for differential expression?

With the DESeq2 median-of-ratios method, which corrects for library size and RNA composition.

References: [HBC training, DESeq2 normalisation](https://hbctraining.github.io/DGE_workshop_salmon_online/lessons/02_DGE_count_normalization.html)

### Are duplicate reads a problem in RNA-seq?

Not necessarily. Highly expressed short transcripts and miRNAs legitimately produce many identical reads. In paired-end genomic data, identical start positions on both reads are unlikely by chance, so duplicate removal is standard there.

### What usually goes wrong in RNA-seq?

- Degraded RNA lowers yield, over-represents 3′ ends or makes the protocol fail
- Residual gDNA in total RNA-seq inflates quantification and creates intronic background
- Too few replicates leave most true differences undetected
- Processing conditions in separate batches confounds biology with batch; plan the design and record batches

References: [Schurch 2016](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4878611/); [Conesa 2016](https://pmc.ncbi.nlm.nih.gov/articles/PMC4728800/)

**Titolo:** Single-cell & Spatial
### Contenuto

### 10x Genomics or Parse Biosciences?

10x captures frozen or fresh live cells in droplets, so the cell suspension must be of high quality on the day. Parse works on fixed cells or nuclei with split-pool barcoding, so samples can be fixed at collection and processed together. Both support sample multiplexing \(oligo-tagged antibodies for 10x, early barcoding for Parse\) and surface-protein measurement. BD Rhapsody pools prepared by users can also be sequenced.

### How many reads per cell, how many cells and how many replicates?

- 10x Genomics 3′ gene expression: at least 20,000 read pairs per cell
- 10x Genomics 5′ v2: 20,000 read pairs per cell for gene expression, plus 5,000 read pairs per T or B cell for V\(D\)J
- Parse Biosciences Evercode WT: at least 20,000 reads per cell \(v2/v3\), at least 10,000 \(v4\)
- Single-cell ATAC \(10x\): 25,000 read pairs per nucleus
- Cells versus depth: with a fixed budget, about one read per cell per gene is optimal and the rest is better spent on more cells
- Replicates: compare conditions with biological replicates \(donors, animals, plants\) analysed as pseudobulk; methods that ignore replicate variation produce false discoveries
- Loading: the multiplet rate rises with cells loaded \(about 0.8% per 1,000 cells on standard 10x chips\)

References: [10x Genomics, 3′ GEX sequencing requirements](https://software.10xgenomics.com/single-cell-gene-expression/sequencing/doc/specifications-sequencing-requirements-for-single-cell-3-ht); [10x Genomics CG000401](https://cdn.10xgenomics.com/image/upload/v1681257195/support-documents/CG000401_TechNote_SeqMetrics_SingleCell5_v2.0_With_BEAM_RevD.pdf); [Parse Biosciences, WT sequencing requirements](https://support.parsebiosciences.com/hc/en-us/articles/14846676930452-What-are-the-run-configuration-and-sequencing-requirements-for-WT-libraries); [10x Genomics, scATAC sequencing requirements](https://www.10xgenomics.com/support/epi-atac/documentation/steps/sequencing/sequencing-requirements-for-single-cell-atac); [Zhang 2020](https://www.nature.com/articles/s41467-020-14482-y); [Squair 2021](https://www.nature.com/articles/s41467-021-25960-2); [TU Dresden DcGC](https://genomecenter.tu-dresden.de/infohub/singleCell/scRNA-Seq-10X.html)

### What do I send for single-cell RNA-seq?

- 10x Genomics: frozen live cell suspension in duplicate; 5 x 10^5 to 1 x 10^6 cells in 1 mL per cryotube \(minimum 100,000 cells in 0.5 mL\); freezing medium growth medium + 20% FBS + 10% DMSO, or 90% FBS + 10% DMSO \(Bambanker for critical samples\); viability above 80%
- Parse Biosciences: frozen fixed cell or nuclei suspension in duplicate, following the Parse fixation protocol

Ship on dry ice overnight for delivery by 12:00, cryotubes inside a cryobox. Live cells can be hand-delivered for same-day processing if planned. Contact the lab before shipping.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I get a clean cell suspension?

Aim for single cells with minimal debris and aggregates and high viability \(10x requires at least 70%; IGATech asks above 80%\). Non-viable and dying cells increase ambient RNA and clumping, which causes chip clogs. Keep cells on ice, pipette gently, filter debris and remove dead cells if needed; IGATech can perform viability QC with dead-cell removal.

References: [10x Genomics CG00053](https://atgc.net.technion.ac.il/files/2025/02/Cell-preparation.pdf)

### What does the single-cell analysis include?

- Primary: cell calling, sequencing and mapping metrics, gene counts, preliminary clustering and cluster markers
- Secondary: filtering, normalisation, dimensionality reduction, Harmony batch correction, clustering, automatic and manual cell-type annotation, differential expression, gene-set, pathway and compositional analysis
- Advanced: gene regulatory networks, trajectories \(pseudotime, RNA velocity\), integration with atlases or other omics

### What is Open-ST and what resolution does it give?

Open-ST turns patterned sequencing flow cells into capture areas with barcoded spots of about 0.6 µm, so whole-transcriptome data are captured at subcellular resolution and aligned to the histology image of the same section; serial sections can be stacked into 3D 'virtual tissue blocks'. IGATech runs it on OCT-embedded frozen tissue and FFPE.

References: [Schott 2024](https://doi.org/10.1016/j.cell.2024.05.055); [Schott 2025](https://pmc.ncbi.nlm.nih.gov/articles/PMC11731217/)

### Should I run a pilot spatial experiment?

Yes. A pilot checks RNA quality, embedding, section placement and permeabilisation for your tissue. IGATech can ship capture areas to your lab or section on site.

References: [Schott 2025](https://pmc.ncbi.nlm.nih.gov/articles/PMC11731217/)

### How deep should spatial transcriptomics be sequenced?

- Open-ST: a standard 3 x 4 mm section needs about 400 M reads \(about 50,000 cells at about 1,000 UMIs per cell\); 500 M reads gave a median of about 800 UMIs; a shallow 100 M-read QC run is possible first. Published libraries were far from saturation, so depth depends on the resolution of information you need

Required depth scales with the area actually covered by tissue.

References: [Schott 2024](https://doi.org/10.1016/j.cell.2024.05.055); [Schott 2025](https://pmc.ncbi.nlm.nih.gov/articles/PMC11731217/)

### How do I check RNA quality before spatial transcriptomics?

Fresh-frozen: cut 3–4 sections of 30 µm into a pre-cooled tube, extract total RNA and check integrity on a TapeStation; RIN above 7 is recommended because capture relies on poly\(dT\) and degraded RNA lowers efficiency. FFPE: extract RNA from 10 µm sections \(about 4 for small samples, 1–2 for large ones\) with an FFPE kit and profile it on an RNA 6000 Pico chip or TapeStation.

References: [Schott 2025](https://pmc.ncbi.nlm.nih.gov/articles/PMC11731217/)

### How do I prepare fresh-frozen tissue for Open-ST?

Freeze and embed as soon as possible: fill a cryomold with OCT without bubbles, place the tissue, freeze the mold in isopentane pre-cooled on dry ice or liquid nitrogen for 1–2 minutes until the OCT is white, and store at −80 °C in an airtight bag. Embed small samples \(organoids, punches under 1 mm2\) close together; cut tissue larger than the capture area into pieces embedded separately. Section at 10 µm and place the section right after the region of interest onto the capture area. Trim excess OCT and work RNase-free.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I prepare FFPE tissue for Open-ST?

Face the block, trim the paraffin to slightly larger than the capture area, cool the block on ice, cut 10 µm sections with a clean blade, float them on a 42 °C Milli-Q water bath and lift one section per capture area without bubbles, then dry fully before shipping. Score tissue that exceeds the capture area into segments with shallow cuts.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I ship spatial samples?

In a slide mailer, capture area and tissue facing up, sealed with parafilm. Fresh-frozen slides on dry ice inside a padded box \(never in direct contact with dry ice\); FFPE slides at room temperature. Contact the lab before preparing samples.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What spatial analyses are available?

QC, pseudo-image generation, cell segmentation aligned to histology, multi-sample integration with batch correction, clustering, cell-type annotation, differential expression, 3D maps, regulatory networks, trajectories, integration with scRNA-seq and interactive viewers.

### What usually goes wrong in single-cell and spatial projects?

- Low viability or debris: ambient RNA blurs cell identities and clogs the chip
- Overloading cells raises the multiplet rate \(estimated at about 0.8% per 1,000 cells loaded on standard 10x chips\), and multiplets look like intermediate cell types
- Spatial: degraded RNA, thick OCT layers, folded sections or tissue outside the capture area reduce usable data

References: [10x Genomics CG00053](https://atgc.net.technion.ac.il/files/2025/02/Cell-preparation.pdf); [TU Dresden DcGC](https://genomecenter.tu-dresden.de/infohub/singleCell/scRNA-Seq-10X.html); [Schott 2025](https://pmc.ncbi.nlm.nih.gov/articles/PMC11731217/)

**Titolo:** DNA methylation
### Contenuto

### Which methylation method fits my question?

- Whole-genome bisulfite \(WGBS\): every cytosine, all contexts, from 50 ng
- Enzymatic methyl-seq \(EM-seq\): every cytosine with less DNA damage; for limited, degraded or FFPE DNA
- RRBS: CpG-rich regions, about 1% of the genome \(MspI for mammals, TaqI for plants\), from 100 ng; for many samples on a budget
- Targeted bisulfite \(human\): selected regions by capture
- Nanopore native DNA: all contexts, 5mC and 5hmC, haplotype-resolved, including repeats and centromeres

References: [Vaisvila 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8256858/)

### Bisulfite or enzymatic conversion?

Bisulfite uses extreme temperature and pH that fragment and lose DNA, so libraries show GC bias and coverage gaps. EM-seq converts with enzymes, giving longer inserts, fewer duplicates, more even GC coverage and more CpGs assessed, even from 100 pg; global methylation levels match WGBS.

References: [Vaisvila 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8256858/)

### Can I tell 5mC from 5hmC?

Not with standard bisulfite or EM-seq: both read 5mC and 5hmC together as 'methylated'. Nanopore calls methyl and hydroxymethyl bases separately on native DNA.

References: [Vaisvila 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8256858/)

### What coverage and how many replicates do I need for methylation studies?

- WGBS reference methylome: 30x per replicate \(equivalent to 15x per strand\)
- WGBS or EM-seq for differentially methylated regions: 5–15x per sample with at least two biological replicates; use about 15x for closely related cell types and short DMRs with small differences. Beyond about 15x, extra replicates add more power than extra depth. Analyse replicates separately, never pooled
- EM-seq: no separate vendor target; at equal read numbers it covers more CpGs than WGBS, so WGBS targets are a conservative upper bound
- RRBS: 30–40 M raw reads per sample \(human or mouse, vendor guidance\); CpGs are usually called at 10x or more
- Targeted methylation capture: 100–250x raw coverage of the probe territory; for a 107 Mb panel, about 55 M 2x100 bp read pairs \(11 Gb\) give 30–50x
- Nanopore 5mC/5hmC: 20x for genome-wide calls, about 30x for haplotype-resolved methylation

References: [ENCODE WGBS standards](https://www.encodeproject.org/data-standards/wgbs/); [IHEC reference epigenome standards](https://ihec-epigenomes.org/research/reference-epigenome-standards); [Ziller 2015](https://www.nature.com/articles/nmeth.3152); [NEB, EM-seq feature article](https://www.neb.com/en/tools-and-resources/feature-articles/enzymatic-methyl-seq-the-next-generation-of-methylome-analysis); [Diagenode RRBS kit manual](https://www.diagenode.com/files/products/kits/RRBS-KIT-V2_manual.pdf); [Lee 2014](https://link.springer.com/article/10.1186/1480-9222-16-1); [Twist Bioscience, methylation workflow poster](https://www.twistbioscience.com/content/dam/twistbioscience/resources/2023-06/An%20end-to-end%20workflow%20for%20accurate%20methylation%20detection%20-%20AACR%202023.pdf); [Illumina, TruSeq Methyl Capture EPIC](https://emea.illumina.com/content/dam/illumina/gcs/assembled-assets/marketing-literature/truseq-methyl-capture-epic-sequencing-panel-data-sheet-m-gl-01451/truseq-methyl-capture-epic-sequencing-panel-data-sheet-m-gl-01451.pdf); [Oxford Nanopore, methylation guide](https://a.storyblok.com/f/196663/x/4687cd8540/methylation-getting-started-guide.pdf)

### What DNA do you need for bisulfite or enzymatic methyl-seq?

Nuclease-free water is preferred \(EDTA accepted up to 0.5 mM\), 5–10 ng/µL by fluorimetry, at least 20 µL, A260/280 and A260/230 above 1.8, RNase-treated, free of proteins, solvents and salts, all samples within ±20%. Check integrity on a 0.8% agarose gel: degraded DNA over-fragments during conversion and gives low-complexity libraries. Ask first for low-input or FFPE samples.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What do you need for Nanopore methylation?

High-molecular-weight DNA as for long-read sequencing \(see the Long reads & Assembly tab\); molecules above 50 kb give the best phasing.

### What does the methylation analysis deliver?

QC, alignment with deduplication, methylation calls at single-cytosine resolution, genome-wide statistics \(CG, CHG and CHH contexts for plants\), Circos views and annotated DMRs. Conversion efficiency is measured with a lambda DNA spike-in. Nanopore adds differentially methylated sites and regions per haplotype, epi-haplotypes, methylation around insertion events, SNP and SV calls and genome browser hosting.

### What usually goes wrong in methylation projects?

- Degraded DNA gives over-fragmented, low-complexity bisulfite libraries
- Incomplete conversion is read as methylation, which is why the lambda spike-in is checked
- Converted libraries have unbalanced base composition and lower mapping rates
- Pooling biological replicates hides variability and reduces DMR specificity

References: [Vaisvila 2021](https://pmc.ncbi.nlm.nih.gov/articles/PMC8256858/); [Ziller 2015](https://www.nature.com/articles/nmeth.3152)

**Titolo:** ChIP, ATAC & Hi-C
### Contenuto

### Do I send chromatin or immunoprecipitated DNA for ChIP-seq?

Immunoprecipitated DNA: the service starts from your IP and input DNA, from which IGATech builds libraries \(picogram amounts are workable\), sequences 150 bp paired-end and analyses the data.

### Which control should I use for ChIP-seq?

Input DNA from the same chromatin is the standard: ENCODE requires an input control matching run type, read length and replicate structure. IgG is less suitable: it is rarely true pre-immune serum from the same animal and pulls down very little DNA, so a few regions get over-amplified during library construction. Untagged strains are a valid control for tagged proteins.

References: [ENCODE histone ChIP-seq standards](https://www.encodeproject.org/chip-seq/histone/)

### How deep should I sequence ChIP-seq, CUT&RUN or CUT&Tag?

Counts are usable fragments per biological replicate \(mapped, filtered, deduplicated\), with at least two replicates.

- Transcription factors: 20 M usable fragments per replicate \(10–20 M is rated low, under 10 M insufficient\)
- Narrow histone marks \(H3K4me3, H3K27ac, H3K9ac, H3K4me2, H2A.Z\): 20 M usable fragments per replicate \(IHEC: 30–50 M aligned reads\)
- Broad histone marks \(H3K27me3, H3K36me3, H3K4me1, H3K79me2, H3K9me1/2, H4K20me1\): 45 M usable fragments per replicate; H3K9me3 in tissues and primary cells: 45 M mapped reads
- Practical rule from depth-saturation studies: 40–50 M reads for most marks in human, often under 20 M in fly
- CUT&RUN: about 10 M paired-end reads in human \(vendor guidance 3–8 M\)
- CUT&Tag: about 3 M paired-end reads suffice for histone marks, even in human

The input control should match the ChIP in run type, read length and replicate structure.

References: [ENCODE TF ChIP-seq standards](https://www.encodeproject.org/chip-seq/transcription_factor/); [ENCODE histone ChIP-seq standards](https://www.encodeproject.org/chip-seq/histone/); [IHEC reference epigenome standards](https://ihec-epigenomes.org/research/reference-epigenome-standards); [Jung 2014](http://nar.oxfordjournals.org/content/early/2014/03/05/nar.gku178.full.pdf); [Skene 2017](https://elifesciences.org/articles/21856); [EpiCypher, CUT&RUN sequencing metrics](https://support.epicypher.com/docs/cut-and-run-sequencing-metrics); [Kaya-Okur 2019](https://doi.org/10.1038/s41467-019-09982-5)

### What DNA do you need for ChIP-seq?

IP and input DNA in water or 10 mM Tris-HCl pH 8.5 at 0.5 ng/µL by fluorimetry, at least 12 µL, A260/280 and A260/230 above 1.8, free of protein, RNA, solvents and salts. Keep samples within ±20%; if normalisation is waived, per-sample coverage is not guaranteed.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How are ChIP-seq peaks called?

With MACS2. It models fragment size from about 1,000 strongly enriched regions \(default fold enrichment 10–30, adjustable when too few regions are found\), extends reads to that length, scales ChIP and control to the same depth and scans windows twice the fragment length. P-values come from a local Poisson model using the control, q-values from Benjamini–Hochberg. Duplicates are capped per position by default; you can keep one or all.

### What do I receive from a ChIP-seq project?

FASTQ, QC reports, annotated peak lists, genome browser tracks and, on request, differential binding between groups.

### Bulk or single-cell ATAC-seq?

Bulk ATAC compares accessibility between conditions or tissues; single-cell ATAC \(10x Chromium\) resolves heterogeneous populations and rare cell types, with thousands of cells per run.

### What do I send for ATAC-seq?

Mammalian cells as frozen cell suspension in duplicate: 300,000 cells in 1 mL per cryotube recommended \(minimum 50,000 cells in 0.5 mL\), on dry ice overnight for delivery by 12:00, in cryoboxes. Live cells can be hand-delivered for same-day processing if planned.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What makes a good ATAC-seq library?

A fragment-size distribution with nucleosome-free and mononucleosome peaks, strong enrichment at transcription start sites, a fraction of reads in peaks \(FRiP\) above 0.2 \(ideally above 0.3\) and high library complexity \(NRF and PBC1 above 0.9\). ENCODE also asks for at least two biological replicates.

References: [ENCODE ATAC-seq standards](https://www.encodeproject.org/atac-seq/)

### How deep should I sequence ATAC-seq?

- Peak calling and differential accessibility: 25 M non-duplicate, non-mitochondrial fragments per replicate \(50 M paired-end reads\), at least two replicates; a widely used review suggests at least 50 M mapped reads
- Transcription-factor footprinting: more than 200 M mapped reads per sample \(empirical estimate; there is no formal standard\)
- Single-cell ATAC \(10x\): 25,000 read pairs per nucleus

Raw output must be higher than these targets, because duplicates and mitochondrial reads are removed first.

References: [ENCODE ATAC-seq standards](https://www.encodeproject.org/atac-seq/); [Yan 2020](https://link.springer.com/article/10.1186/s13059-020-1929-3); [10x Genomics, scATAC sequencing requirements](https://www.10xgenomics.com/support/epi-atac/documentation/steps/sequencing/sequencing-requirements-for-single-cell-atac)

### What does the ATAC-seq analysis deliver?

FASTQ, QC, duplicate-marked BAMs, peak calls with annotation and a consensus peak matrix, differential accessibility with fold changes and p-values, R objects and genome browser sessions.

### What can Hi-C tell me besides genome assembly?

A/B compartments \(active versus inactive chromatin\), topologically associating domains \(TADs\) and chromatin interactions, and how variants or conditions change them; it can be integrated with ChIP-seq and RNA-seq. For the depth needed for each goal, see “How deep should I sequence Hi-C for assembly, compartments, TADs or loops?”

### How deep should I sequence Hi-C for assembly, compartments, TADs or loops?

Depth depends on the question; counts are read pairs unless stated, and only a fraction become valid contacts.

- Genome scaffolding \(chromosome-scale assembly\): more than 50x coverage of the haploid genome \(more than 100x if Hi-C reads are also used for polishing\); the Vertebrate Genomes Project sequenced Hi-C at about 60x. Vendor guidance converts to about 200 M paired-end reads per Gb of genome, with more for fragmented contigs
- A/B compartments: the least demanding goal, readable from sparse data; vendor guidance is more than 50 M reads, analysed at 1–10 Mb bins
- TADs: about 100 M valid \(mapped junction\) reads support 40 kb resolution in human, the bin size used when TADs were first defined; vendor guidance is more than 200 M reads, and finer bins need more
- Chromatin loops \(5–10 kb\): at least 600 M read pairs per sample and at least two samples; the human kilobase-resolution reference map used 4.9 billion contacts. There is no formal minimum: sparser maps simply call fewer loops
- Resolution is defined as the smallest bin size at which 80% of bins have at least 1,000 contacts

References: [Earth BioGenome Project assembly recommendations](https://www.earthbiogenome.org/report-on-assembly-recommendations); [Rhie 2021](https://www.nature.com/articles/s41586-021-03451-0); [Arima, Hi-C for genome assembly](https://arimagenomics.com/wp-content/files/eBook-Hi-C-for-Genome-Assembly.pdf); [Arima, Hi-C for 3D genome](https://arimagenomics.com/wp-content/files/Product-Flyer-The-Arima-HiC-Kit-for-Reproducible-3D-Genome-Conformation-Analyses.pdf); [Lajoie 2015](https://pmc.ncbi.nlm.nih.gov/articles/PMC4347522/); [Dixon 2012](https://pmc.ncbi.nlm.nih.gov/articles/PMC3356448/); [Arima, Bioinformatics user guide](https://arimagenomics.com/wp-content/files/Bioinformatics-User-Guide-Arima-HiC-and-Arima-High-Coverage-HiC.pdf); [Rao 2014](https://doi.org/10.1016/j.cell.2014.11.021)

### What material do you need for Hi-C?

Plants: at least 10 g of flash-frozen young leaves or buds in 15/50 mL Falcon tubes on dry ice. Mammalian cells: frozen cell suspension in duplicate, 5 x 10^6 cells in 1 mL per cryotube recommended \(minimum 100,000 cells in 0.5 mL\); ask first below 1 million cells or above 24 samples. Ship on dry ice overnight for delivery by 12:00, cryotubes in a cryobox. Live cells can be hand-delivered for same-day processing if planned.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What usually goes wrong in chromatin assays?

- Antibodies that do not meet characterisation standards give weak enrichment that depth cannot rescue
- IgG controls with very little DNA create amplification artefacts
- Low library complexity \(low NRF/PBC\) limits usable fragments
- One replicate per condition prevents reproducibility checks \(IDR\) and differential analysis

References: [ENCODE histone ChIP-seq standards](https://www.encodeproject.org/chip-seq/histone/); [ENCODE ATAC-seq standards](https://www.encodeproject.org/atac-seq/)

**Titolo:** Microbiome
### Contenuto

### Metabarcoding, shotgun metagenomics or metatranscriptomics?

- Metabarcoding: one marker gene \(16S, ITS, 18S or custom\); tells who is there and relative abundance; lowest cost
- Shotgun metagenomics: all DNA; taxonomy to species level, functional potential, metagenome-assembled genomes \(MAGs\), resistance genes; abundant organisms dominate the reads, so rare members need more depth
- Metatranscriptomics: rRNA-depleted RNA; which genes and pathways are active; high depth needed for low-expressed genes

### Which marker should I use for metabarcoding?

16S rRNA for bacteria and archaea, ITS for fungi, 18S for eukaryotes; short reads up to 300 bp on NovaSeq X Plus or AVITI, or full-length markers on Nanopore with duplex basecalling \(about Q30\). Other primer sets can be run; untested primers need a protocol optimisation \(8 representative samples, two annealing temperatures, three template dilutions\).

### What is the difference between the Value and Focus levels?

With Value, samples that fail amplification while others in the batch succeed are considered a sample problem and are not repeated. Focus includes one extra preparation round for low-yield samples, with minor changes \(template dilution, annealing temperature\). In both, low-yield samples are sequenced at your request with full charge, otherwise only library preparation is charged.

### Which controls must I include?

Positive controls \(mock communities\) and negative controls \(extraction and PCR blanks\), sequenced with the samples. They are essential for low-biomass samples, where reagent contaminants and cross-contamination can make up a large part of the reads; follow the RIDE checklist \(report methodology, include negative controls, determine the level of contamination, explore contamination downstream\).

References: [Eisenhofer 2019](https://doi.org/10.1016/j.tim.2018.11.003)

### Will human DNA be a problem in microbiome data?

It depends on the human-to-microbial DNA ratio: stool \(under 10% human DNA\) and skin \(under 90%\) are usually unaffected, while biopsies with over 97% human DNA are heavily affected. In shotgun data, host reads also take sequencing capacity.

### How deep should I sequence microbiome samples?

- 16S metabarcoding: 15,000–100,000 reads per sample are generally sufficient for classification; about 2,000 reads already recover between-sample patterns. Check rarefaction curves, especially for diverse samples such as soil
- ITS metabarcoding: community dissimilarity stabilises above about 10,000–20,000 reads per sample \(soil fungi\)
- Shallow shotgun for taxonomy: about 0.5 M reads per sample as an alternative to 16S; 1 M reads gave less than 1% dissimilarity to the full taxonomic profile \(high-biomass samples such as stool\)
- High host DNA \(e.g. 90%\): sensitivity drops sharply even at 25 M reads, so plan more depth or host depletion
- Antimicrobial resistance genes: at least 80 M reads per sample for the full richness of AMR gene families
- Strain level and genomes: about 0.5–1 Gb for reference-based strain-level taxonomy, about 2 Gb for functional pathways, more than 10 Gb for de novo MAGs; simulations put the MAG sweet spot near 60 M reads
- Metatranscriptomics: at least 40 M raw reads per sample \(human stool\); without depletion, rRNA can exceed 90% of reads

References: [Illumina, 16S metagenomics FAQ](https://www.illumina.com/content/dam/illumina-marketing/documents/applications/microbiology/microbial-sequencing-methods/faq_16S_2014-09-16.pdf); [Caporaso 2011](https://doi.org/10.1073/pnas.1000080107); [Smith 2014](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0090234); [Hillmann 2018](https://doi.org/10.1128/mSystems.00069-18); [Gweon 2019](https://doaj.org/article/0d44895d887e4f3a9d6d056e7219808b); [Pereira-Marques 2019](https://www.frontiersin.org/article/10.3389/fmicb.2019.01277); [Zaheer 2018](https://open-science.canada.ca/items/0ca15501-1cd6-4d6b-a64c-c354194723e4/full); [Treichel 2026](https://ucrisportal.univie.ac.at/en/publications/benchmarking-of-shotgun-sequencing-depth-reveals-the-potential-an/); [Rocha 2024](https://www.biorxiv.org/content/10.1101/2023.05.02.539054); [Westreich 2016](https://bmcbioinformatics.biomedcentral.com/articles/10.1186/s12859-016-1270-8); [Shakya 2019](https://www.frontiersin.org/journals/genetics/articles/10.3389/fgene.2019.00904/full)

### What DNA or amplicons do you need for metabarcoding?

DNA or amplicons in water or 10 mM Tris-HCl pH 8.5, 5–50 ng/µL by fluorimetry, at least 25 µL, A260/280 and A260/230 above 1.8, samples within ±20%. For amplicons, state amplicon length, primer sequences and overhangs in the spreadsheet:

- Nextera: forward 5′-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-\[locus\]; reverse 5′-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAG-\[locus\]
- TruSeq: forward 5′-CTCTTTCCCTACACGACGCTCTTCCGATCT-\[locus\]; reverse 5′-TGGAGTTCAGACGTGTGCTCTTCCGATCT-\[locus\]

Amplicons without overhangs must be declared at quotation.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### What do you need for shotgun metagenomics and metatranscriptomics?

- Standard short-read DNA: 2–30 ng/µL, at least 25 µL
- Low-input short-read DNA: below 2 ng/µL, at least 25 µL \(below 10 ng total a dedicated protocol is used\)
- PCR-free short-read DNA: 10–50 ng/µL, at least 25 µL
- Long-read DNA: above 20 ng/µL, at least 100 µL
- Metatranscriptomics total RNA: at least 200 ng, 20 ng/µL, 10 µL, DNase I mandatory

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### How do I collect and ship stool samples?

Up to 48 samples: 0.5–1 g of faeces in a Zymo R1103 tube pre-filled with 1 mL DNA/RNA Shield and 0.5 mm beads, leaving at least 30% of the tube empty. Above 48 samples: deep 96-well plates with 600 µL of suspension per well, sealed with heat-resistant, pierceable seals. Faeces frozen without preservative or stored in ethanol must be transferred into DNA/RNA Shield \(ethanol samples pelleted and washed in PBS first\). Ship in a sealed bag inside a padded box at room temperature.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### Do I need a DNase treatment?

Yes for total RNA-seq and metatranscriptomics, where it is mandatory: genomic DNA inflates RNA quantification and adds intronic and intergenic noise. It is not required for mRNA-seq or small RNA-seq.

### What does the microbiome analysis deliver?

- Metabarcoding: FASTQ and MultiQC, OTU or ASV tables, taxonomy \(bar plots, heatmaps, Krona\), alpha and beta diversity, rarefaction, phylogenetic tree, group statistics, custom databases
- Metagenomics: taxonomy from domain to species, functional and pathway annotation, MAGs with completeness and contamination, resistance genes
- Metatranscriptomics: de novo assembly, taxonomy, predicted genes and proteins, functional annotation, normalised and differential expression

Extra metadata columns in the spreadsheet drive the statistics.

### What usually goes wrong in microbiome projects?

- PCR inhibitors block amplification; clean-up or dilution helps, but dilution also lowers sensitivity
- Low-biomass samples without blanks cannot be distinguished from reagent contamination
- Adapter or primer dimers \(a 120–170 bp peak\) compete for reads; they come from low or degraded input
- Differences between values declared in the spreadsheet and measured values shift responsibility for failed libraries to the customer

References: [Eisenhofer 2019](https://doi.org/10.1016/j.tim.2018.11.003)

**Titolo:** Biotech
### Contenuto

### Which assay answers which biotech question?

- Is my vector or cassette intact? INTEGRITY: deep sequencing of tens of kb of vector or cassette
- Are there rare mutations after propagation or subcloning? Duplex-Seq ultra-low mutation assay \(variants around 0.1%\)
- Where did the transgene integrate, how many sites, is the clone monoclonal? Integration-site analysis
- Has the cell line or strain rearranged? Long-read de novo assembly \(an alternative to FISH for large rearrangements\)
- Is my plasmid correct? Long-read full-length plasmid sequencing
- Is the cell bank in the expected state? Bulk, single-cell or long-read RNA-seq, ribosome profiling

### Why is integration-site analysis harder than it looks?

Randomly integrated transgenes often insert as multicopy concatemers and can delete or rearrange host DNA at the insertion site, so PCR-based methods such as inverse PCR often fail. Proximity-based targeted methods \(e.g. targeted locus amplification\) or reads spanning the junction resolve the insertion site, transgene content and local structural changes.

References: [Cain-Hom 2017](https://pmc.ncbi.nlm.nih.gov/articles/PMC5416772/); [Goodwin 2019](https://genome.cshlp.org/content/29/3/494)

### How does NGS support regulatory dossiers?

Guidelines such as ICH Q5B expect nucleic-acid analysis to verify the coding sequence and physical state of the expression construct in the master cell bank. NGS also supports identity, genetic stability over time, contamination and viral detection. Whether a dataset meets a regulator's requirements must be agreed with IGATech and your regulatory team.

References: [ICH Q5B \(EMA\)](https://www.ema.europa.eu/en/ich-q5b-analysis-expression-construct-cell-lines-used-production-rdna-derived-protein-products-scientific-guideline)

### What is Duplex-seq and when do I need it?

Duplex sequencing tags both strands of each original DNA molecule and keeps only mutations seen on both, which removes most PCR and sequencing errors \(theoretical background below one error per 10^9 bases\). Use it for ultra-rare somatic variants, mutagenesis or mixed populations; IGATech's targeted Duplex-Seq assay detects variants at around 0.1%. It needs at least 1 µg of DNA and deep sequencing.

References: [Schmitt 2012](https://pubmed.ncbi.nlm.nih.gov/22853953/)

### How should I sequence a bacterial genome or a plasmid?

For a closed chromosome and complete plasmids, long reads assemble the replicons and short reads polish residual errors; this hybrid, long-read-first route is the current reference approach. Long-read-only assemblers often miss or misassemble small plasmids, so tell us if small plasmids matter. Short reads alone suit large SNP-typing or screening batches. For depth, see “What coverage do I need for WGS and exome?”

References: [Wick 2023](https://pubmed.ncbi.nlm.nih.gov/36862631/); [Bouras 2023](https://pmc.ncbi.nlm.nih.gov/articles/PMC10760025/)

### What material do you need for biotech assays?

- Integrome and Duplex-seq: DNA at 20–30 ng/µL, at least 1 µg total, in 10 mM Tris-HCl pH 8.5, at least 35 µL. Input caps sensitivity: the number of independent molecules limits how rare a variant can be detected
- Assemblies and long-read integration analysis: HMW DNA \(see the Long reads & Assembly tab\)
- Transcriptomes: RNA as in the Transcriptomics tab \(picogram inputs possible\)
- Cell pellets can be extracted by IGATech \(see the Sample logistics tab\)

References: [Schmitt 2012](https://pubmed.ncbi.nlm.nih.gov/22853953/)

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

**Titolo:** Run Only
### Contenuto

### Which AVITI flow cell fits my project?

- High output 2x150 bp: 300 Gb, 1,000 M reads
- High output 1x150 / 2x75 bp: 150 Gb, 1,000 M reads
- High output 2x300 bp: 180 Gb, 300 M reads
- Medium output 2x150 bp: 150 Gb, 500 M reads
- Medium output 1x150 / 2x75 bp: 75 Gb, 500 M reads
- Medium output 2x300 bp: 60 Gb, 100 M reads

Standard read set-ups exist for 10x 3′ gene expression, 10x ATAC and Multiome, BD Rhapsody and Open-ST.

### Can my Illumina-style library run on AVITI?

IGATech's AVITI service accepts TruSeq- and Nextera-style libraries. Element's Adept workflow makes third-party libraries compatible and requires full-length libraries without 5′ or 3′ additions or truncations, with dual indexes up to 10 bp, so declare any custom construct in advance.

References: [Element Adept workflow](https://www.elementbiosciences.com/products/adept)

### What library specifications do you need?

- Illumina \(NovaSeq X Plus\): libraries 5–50 ng/µL by fluorimetry, at least 25 µL
- Element AVITI: libraries 5–50 ng/µL, at least 25 µL; pools at least 10 ng/µL, at least 30 µL

Buffer: 10 mM Tris-HCl pH 8.5 or another commercial DNA resuspension buffer. Mandatory in the Libraries Spreadsheet: library kit, index sequences and names for demultiplexing, and the full adapter sequences for home-made constructs.

Video guide – IGATech Customer Portal: [English](https://www.youtube.com/watch?v=9YnPiskSgnk) | [Italiano](https://www.youtube.com/watch?v=Rrv6aDozPts)

### My library has low base diversity: what should I do?

Declare it. Illumina uses the first 25 cycles of read 1 for quality metrics, so libraries with non-random bases there \(internal barcodes, primer or restriction sites, homopolymers\) lower pass-filter rates and quality scores. If declared, IGATech balances the run with a well-balanced library such as PhiX; if not declared, the full service is charged without re-sequencing.

### How do I avoid index hopping?

Use unique dual indexes \(each i5 and i7 used once in the pool\), remove free adapters, store libraries individually at −20 °C and pool just before sequencing. On patterned flow cells, hopping typically affects 0.1–2% of reads; with unique dual indexes, hopped reads are assigned to 'undetermined'.

References: [Illumina, Index hopping](https://www.illumina.com/techniques/sequencing/ngs-library-prep/multiplexing/index-hopping.html)

### Why is depth uneven between my libraries?

Reads are shared in proportion to the molar amount of each library loaded. Pool in equimolar ratios after accurate quantification; libraries with very different size ranges need separate pools and extra runs. Uneven depth reflects pooling, not sequencing quality.

### What usually goes wrong with custom libraries?

- Adapter dimers \(a 120–170 bp peak\) cluster efficiently and take reads; clean libraries before shipping
- Missing or wrong index sequences in the spreadsheet stop demultiplexing
- Undeclared low-diversity libraries degrade quality metrics
- Combinatorial indexes on patterned flow cells let hopped reads be assigned to the wrong sample

References: [Illumina, Index hopping](https://www.illumina.com/techniques/sequencing/ngs-library-prep/multiplexing/index-hopping.html)

### How do I receive Run Only data?

Through a fast EU data platform or IGATech's servers, with download from the Customer Portal.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

**Titolo:** Data & Bioinformatics
### Contenuto

### What sequencing depth should I ask for?

There is no universal number: it depends on application, field and journal. Each base must be read several times, coverage is never even, and rare variants in heterogeneous samples or rarely expressed genes need more depth. Recommended depth for each sub-application, with references, is given in the section of each application.

### How do I receive and download my data?

The Customer Portal notifies you when results are ready and hosts the download; the PDF report describes methods, materials and every file.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

### Where do I find how my samples were processed?

In the PDF report delivered with the data: it describes methods, materials and every delivered file.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

### Which bioinformatics support levels exist?

- Bronze: standard pipelines with results ready for biological interpretation \(RNA-seq, DNA-seq, ChIP-seq, metagenomics, de novo assembly, single-cell and others\)
- Silver: Bronze plus custom data manipulation and publication-ready graphics
- Gold: from experimental design to custom analysis, pipelines and software, with dedicated bioinformaticians
- Platinum: stage-by-stage support over long projects, with pipelines revised as data arrive

### Are adapters removed from my reads?

Raw reads keep their full length: adapter read-through is masked by replacing with N any stretch of at least 5 bp that matches the sample's own adapter \(barcode included\). Raw data are not quality-trimmed; the standard analysis pipelines trim.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

### Where are the UMIs in my data?

UMIs are read after the i7 index, never inside read 1 or read 2. They are split off during demultiplexing and written into the read name, so no removal is needed.

Video guide – IGATech Data Download: [English](https://www.youtube.com/watch?v=eHBpLWHfKRI) | [Italiano](https://www.youtube.com/watch?v=KnyAaXO9ghM)

### Are duplicate reads a problem in RNA-seq?

Not necessarily. Highly expressed short transcripts and miRNAs legitimately produce many identical reads. In paired-end genomic data, identical start positions on both reads are unlikely by chance, so duplicate removal is standard there.

### Why is depth uneven between my libraries?

Reads are shared in proportion to the molar amount of each library loaded. Pool in equimolar ratios after accurate quantification; libraries with very different size ranges need separate pools and extra runs. Uneven depth reflects pooling, not sequencing quality.